Description
| Model | PS-SC200 | |||||
| Certificates | ETL,CETL,FCC |
|
||||
| output | DC Voltage | 12V / 24V | ||||
| Voltage Tolerance | ±0.5V | |||||
| Rated current | 16.7A/ 8.3A | |||||
| Rated power | 150W | |||||
| input | Voltage Range | 100~130VAC | ||||
| Frequency Range | 50~60HZ | |||||
| Power Factor (Typ.) | PF≥0.65 | |||||
| Efficiency(Typ.) | 83% | |||||
| AC Current(Typ.) | 1.45A | 1.45A | ||||
| Leakage current | <0.70mA/110VAC | |||||
| Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed | ||||
| Over Current | ≤1.4*I out | |||||
| Over Loading | ≤120% | |||||
| Over temperature | 100℃±10℃ (The output voltage will turn off when the temperature is higher then100℃±10℃, after the temperature drop off ,it will recovery) automatic
|
|||||
| Environment | Working TEMP. | -40~+70℃ | ||||
| Working Humidity | 20~90%RH, non-condensing | |||||
| Storage TEMP. Humidity | -40~+80℃,10~95%RH | |||||
| TEMP .coefficient | ±0.03%/℃(0~50℃) | |||||
| Vibration | 10~500Hz,2G 10min./1 cycle,period for 60min. each along X,Y,Z axes
|
|||||
|
Safety& EMC |
Safety standards | UL1012 | ||||
| Withstand voltage | I/P-O/P:1500KVAC | |||||
| Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | |||||
| EMC EMISSION | FCC Part 15 B | |||||
| others | Net. Weight | 1.8Kg | 1.7Kg | |||
| Size | 230*78*46mm(L*W*H) | 380*77*57mm(L*W*H) | ||||
| packing | 324*279*176mm 10PCS/CTN | |||||
| Notes | 1. All parameters if NOT specially mentioned are measured at 110VAC input , rated load and 25℃of ambient temperature.
2. To extend the driver’s using life ,please reduce the loading at lower input voltage. 3.Loading should be 5-100%. |
|||||



Reviews